Magnetic Thickness Tool for Casing Corrosion Detection
Project Overview
On August 11, 2026, A-One Oil Company conducted EMFD43C magnetic thickness logging in a certain oilfield block. The survey identified severe casing corrosion in the interval 1833.6 m – 1838.6 m.
Key Findings
Casing Specs (in): 7
Standard Wall Thickness (mm): 8.05
Remaining Thickness (mm): 6.65
Metal Loss Rate (%): 17.36
Conclusion
The casing in the target interval is perforated and severely deformed, indicating critical integrity failure requiring immediate remediation.