Description
Slim-Profile Multi-Parameter Logging for Reliable Cased-Hole Evaluation
The 1-11/16″ Gamma Ray Temperature CCL Tool is a compact, high-precision downhole logging instrument designed for cased-hole formation evaluation, depth correlation, and thermodynamic profiling. The slim 1-11/16-inch diameter enables access to tight boreholes and narrow production tubing, while delivering natural gamma radiation, temperature, and Casing Collar Locator (CCL) measurements in a single run. This integrated tool supports essential diagnostic workflows throughout drilling, completion, and production operations - from depth correlation and lithology indication to leak detection and well integrity assessment.
Built on established wireline logging measurement principles, this tool provides repeatable, engineering-grade data that supports confident decision-making in high-stakes wellbore evaluations.
Core Functions & Why They Matter
Gamma Ray Logging - Formation Signal Through Casing
Gamma ray logging detects naturally occurring gamma radiation emitted by subsurface formations. A scintillation detector - typically a sodium iodide (NaI) crystal coupled with a photomultiplier - records the intensity of gamma counts as the tool traverses the well. Differences in gamma counts correlate with formation lithology (e.g., shale vs. sandstone), enabling:
◆ Depth correlation across wells and logging runs
◆ Lithology indication through casing
◆ Identification of radioactive zones for geologic markers
For cased-hole operations, gamma ray reference data becomes a primary depth correlation log, serving as a baseline for aligning other measurements and verifying formation tops even behind multiple casing strings.
Temperature Logging - Wellbore Thermal Profiling
Temperature measurements in a wellbore provide insight into fluid movement, leak detection, and thermal anomalies. The tool incorporates an accurate PT100 temperature sensor with a linear, high-resolution response. Typical specifications include:
◆ Temperature range: –25 °C to 175 °C
◆ Precision: ±1 °C
◆ Resolution: 0.05 °C
◆ Fast response time: ≤ 1 s
This data is essential for identifying thermally sensitive events, such as cooler fluid influx (indicating communication with other zones) or temperature gradients associated with fluid migration.
Casing Collar Locator (CCL) - Depth Calibration Backbone
The CCL measurement subsystem detects changes in metal thickness at casing joints using magnetics. As the tool passes a collar, variations in the magnetic field induce a signal spike, known as a "collar kick." These spikes precisely mark collar locations, enabling absolute depth control and alignment of all other logs to true well depths.
Depth correction using CCL is fundamental in cased-hole logging workflows - especially when correlating data from different logging runs, perforation depths, or production intervals.



Technical Parameters
|
General Spec |
|
|
Maximum Pressure |
15,000PSI (103MPa) |
|
Minimum Temperature |
-4 °F (-20°C) |
|
Maximum Temperature |
350°F (175°C) |
|
Diameter |
43mm (1-11/16 in) |
|
Tool Length |
1230mm (48.42in) |
|
Effective Length |
1180mm (46.45in) |
|
Weight |
7.5kg (16.53lbs) |
|
Maximum Logging Speed |
32 ft/min (600 m/h) |
|
Working Voltage |
15VDC~30VDC |
|
Zero Length |
GR Section - 15.15in (385mm) |
|
CCL Section - 37.91in (963mm) |
|
|
Temperature Section - 6.5in(165mm) |
|
|
Gamma |
|
|
Test Range Resolution |
0 ~10,000 CPS 1 CPS |
|
Background Noise |
≥100 CPS |
|
Sensor Type |
NaI |
|
Fluctuation Range |
≤ 7% |
|
High-Pressure Range |
< 2000V |
|
Dynamic Range |
10 kHz ~ 50 kHz |
|
SNR |
≥ 5 kHz |
|
Temperature |
|
|
Probe Type |
PT100 |
|
Test Range |
-13°F ~ 350°F (-25°C~175°C) |
|
Accuracy |
±1.8°F (±1°C) |
|
Resolution |
0.09°F (0.05°C) |
|
Response Time |
≤ 1S |
|
CCL |
|
|
Signal Range |
0 ~3300 (mv) |
|
SNR |
≥ 5 kHz |
|
Signal Transmission |
|
|
Tool Bus Type |
CAN |
|
Signal Transmission Rate |
1Mbit/s |
Applications in Cased-Hole Evaluation
The multifunctional capability of this tool supports a range of critical downhole logging applications:
◆ Depth correlation for cased-hole logs-gamma ray and CCL data provide accurate depth markers.
◆ Temperature profiling for leak detection-identify abnormal gradients.
◆ Lithology indication through casing-gamma logs reflect formation facies changes.
◆ Perforation interval validation-combine gamma and CCL for perforation depth confirmation.
◆ Production analysis & reservoir monitoring-interpretable trends when combined with other logs.
Why Choose Our 1-11/16″ Gamma Ray Temperature CCL Tool?
Slim, versatile design for narrow wells and coiled tubing deployment.
Integrated multi-parameter measurements from a single tool run - reducing rig time and operational cost.
Engineering-graded sensor suite delivering dependable, stable data for correlation and interpretation.
Optimized for cased-hole workflows, aligning formation, temperature, and depth information with precision.
The 1-11/16″ Gamma Ray Temperature CCL Tool delivers correlated, high-resolution formation, temperature, and depth control data essential for modern well evaluation and reservoir management. The compact design and robust measurement suite make it a trusted choice for operators seeking efficient, scientifically sound logging solutions in cased-hole environments.
Hot Tags: 1-11/16″ gamma ray temperature ccl tool, China 1-11/16″ gamma ray temperature ccl tool manufacturers, suppliers, factory