info@a-oneoil.com    +86-029-38001009
Cont

Have any Questions?

+86-029-38001009

1-11/16″ Gamma Ray Temperature CCL Tool
video
1-11/16″ Gamma Ray Temperature CCL Tool

1-11/16″ Gamma Ray Temperature CCL Tool

Diameter Size: OD 43mm (1 11/16”)
Temperature: 175℃
Feature: Combined with other logging tools from A-One Oil company for use in well logging.
Application:Using a high-resolution temperature logger to evaluate the leakage inspection.
Send Inquiry
Chat Now

Product Introduction

Description

 

Slim-Profile Multi-Parameter Logging for Reliable Cased-Hole Evaluation

The 1-11/16″ Gamma Ray Temperature CCL Tool is a compact, high-precision downhole logging instrument designed for cased-hole formation evaluation, depth correlation, and thermodynamic profiling. The slim 1-11/16-inch diameter enables access to tight boreholes and narrow production tubing, while delivering natural gamma radiation, temperature, and Casing Collar Locator (CCL) measurements in a single run. This integrated tool supports essential diagnostic workflows throughout drilling, completion, and production operations - from depth correlation and lithology indication to leak detection and well integrity assessment.

Built on established wireline logging measurement principles, this tool provides repeatable, engineering-grade data that supports confident decision-making in high-stakes wellbore evaluations.

 

Core Functions & Why They Matter

 

Gamma Ray Logging - Formation Signal Through Casing

Gamma ray logging detects naturally occurring gamma radiation emitted by subsurface formations. A scintillation detector - typically a sodium iodide (NaI) crystal coupled with a photomultiplier - records the intensity of gamma counts as the tool traverses the well. Differences in gamma counts correlate with formation lithology (e.g., shale vs. sandstone), enabling:

◆ Depth correlation across wells and logging runs

◆ Lithology indication through casing

◆ Identification of radioactive zones for geologic markers

 

For cased-hole operations, gamma ray reference data becomes a primary depth correlation log, serving as a baseline for aligning other measurements and verifying formation tops even behind multiple casing strings.

 

Temperature Logging - Wellbore Thermal Profiling

Temperature measurements in a wellbore provide insight into fluid movement, leak detection, and thermal anomalies. The tool incorporates an accurate PT100 temperature sensor with a linear, high-resolution response. Typical specifications include:

◆ Temperature range: –25 °C to 175 °C

◆ Precision: ±1 °C

◆ Resolution: 0.05 °C

◆ Fast response time: ≤ 1 s

This data is essential for identifying thermally sensitive events, such as cooler fluid influx (indicating communication with other zones) or temperature gradients associated with fluid migration.

 

Casing Collar Locator (CCL) - Depth Calibration Backbone

The CCL measurement subsystem detects changes in metal thickness at casing joints using magnetics. As the tool passes a collar, variations in the magnetic field induce a signal spike, known as a "collar kick." These spikes precisely mark collar locations, enabling absolute depth control and alignment of all other logs to true well depths.

Depth correction using CCL is fundamental in cased-hole logging workflows - especially when correlating data from different logging runs, perforation depths, or production intervals.

Integrated Gamma Temperature CCL Tool 2
Integrated Gamma Temperature CCL Tool 1
Integrated Gamma Temperature CCL Tool M

 

Technical Parameters

 

General Spec

Maximum Pressure

15,000PSI (103MPa)

Minimum Temperature

-4 °F (-20°C)

Maximum Temperature

350°F (175°C)

Diameter

43mm (1-11/16 in)

Tool Length

1230mm (48.42in)

Effective Length

1180mm (46.45in)

Weight

7.5kg (16.53lbs)

Maximum Logging Speed

32 ft/min (600 m/h)

Working Voltage

15VDC~30VDC

Zero Length

GR Section - 15.15in (385mm)

CCL Section - 37.91in (963mm)

Temperature Section - 6.5in(165mm)

Gamma

Test Range

Resolution

0 ~10,000 CPS

1 CPS

Background Noise

≥100 CPS

Sensor Type

NaI

Fluctuation Range

≤ 7%

High-Pressure Range

< 2000V

Dynamic Range

10 kHz ~ 50 kHz

SNR

≥ 5 kHz

Temperature

Probe Type

PT100

Test Range

-13°F ~ 350°F (-25°C~175°C)

Accuracy

±1.8°F (±1°C)

Resolution

0.09°F (0.05°C)

Response Time

≤ 1S

CCL

Signal Range

0 ~3300 (mv)

SNR

≥ 5 kHz

Signal Transmission

Tool Bus Type

CAN

Signal Transmission Rate

1Mbit/s

 

Applications in Cased-Hole Evaluation

 

The multifunctional capability of this tool supports a range of critical downhole logging applications:

 

◆ Depth correlation for cased-hole logs-gamma ray and CCL data provide accurate depth markers.
◆ Temperature profiling for leak detection-identify abnormal gradients.
◆ Lithology indication through casing-gamma logs reflect formation facies changes.
◆ Perforation interval validation-combine gamma and CCL for perforation depth confirmation.
◆ Production analysis & reservoir monitoring-interpretable trends when combined with other logs.

 

Why Choose Our 1-11/16″ Gamma Ray Temperature CCL Tool?

 

Slim, versatile design for narrow wells and coiled tubing deployment.

Integrated multi-parameter measurements from a single tool run - reducing rig time and operational cost.

Engineering-graded sensor suite delivering dependable, stable data for correlation and interpretation.

Optimized for cased-hole workflows, aligning formation, temperature, and depth information with precision.

 

The 1-11/16″ Gamma Ray Temperature CCL Tool delivers correlated, high-resolution formation, temperature, and depth control data essential for modern well evaluation and reservoir management. The compact design and robust measurement suite make it a trusted choice for operators seeking efficient, scientifically sound logging solutions in cased-hole environments.

 

Request a Technical Datasheet

 

 

Hot Tags: 1-11/16″ gamma ray temperature ccl tool, China 1-11/16″ gamma ray temperature ccl tool manufacturers, suppliers, factory

Send Inquiry

(0/10)

clearall